Valve Installation Guide
WARNING: Before Removal and INstallation
Take all necessary safety precautions and comply with the safety manuals for your
equipment.
Please wear your PPE (personal protective equipment), i.e. safety glasses, gloves
and hard hat if necessary.
Confirm that your equipment is immobilized (chock tires).
Lay out a safety perimeter.
Do not perform work on a hydraulic system that is hot and/ or under pressure.
Hot oil can cause serious burns and infection.
NEVER touch a pressurized hose with your
hand and if you suspect a hydraulic injection injury has occurred, get to an emergency
room right away!
Disconnect the remote pendant (yellow push button remote), to minimize
accidental activation of the Hydraulic Power Unit (HPU).
-------------------------------------------------------------------------------------------------------------
Proper valve installation is important to insure that your valve and the equipment that the valve
will be installed will function correctly. Before installation of any valve assemblies into a
manifold, please visual check the cavities for burrs and/ or metal shavings. All O-Rings must be
lubricated on valve cartridge to insure that the O-Rings can be installed into the manifold cavity
without being damaged.
1. Insure there are no foreign objects or contaminates in valve cavities.
2. Lubricate all O-Rings and Back-Up Rings on the valve body. Insert the valve into
the cavity, and then hand tight. Use a 7/8 deep socket with a ratchet for the
Directional Valve (LSV2-08-4CO) and a 15/16 deep socket with a ratchet for the
Load Holding Valve (LSPC-080-4-00).
3. Once the valve is installed, use torque wrench to torque the valve cartridge to
18 FT/LBS Maximum.
• Failure to lubricate the O-Rings prior to installation may cause damage to the
O-Rings; caused by extrusion and/ or shearing of the O-Ring. Please insure to use
Hydraulic Fluid to lubricate all O-Rings and Back-Up Rings.
• Be sure to use the proper hydraulic fluid. Do not use grease, motor oil or WD-40.
Mixing of hydraulic fluid with other lubricants will cause valve failure, due to
contamination. Some lubricants are incompatible because of differences in additive
chemistry that lead to undesirable chemical reactions. If these oils are mixed,
insoluble material may form and then deposit onto sensitive machine surfaces. For a
hydraulic fluid, this could lead to lubricant starvation, valve failure or increased wear.
Mechanical problems leading to shorter equipment life can occur, sometimes
catastrophically. Please review KTI Hydraulics, Inc. Fluid Recommendations
• Do not over torque the valve(s) during installation. Over torquing will cause damage
to the valve assembly.